HomeMy WebLinkAboutPSD-065-06 REPORT PLANNING SERVICES Meeting: GENERAL PURPOSE AND ADMINISTRATION COMMITTEE Date: Monday, June 5, 2006 Report #:File #: By-law #: PSD-065-06 ZBA 2006-0003 Subject: REZONING TO PERMIT A GAS STATION, CAR WASH AND CONVENIENCE STORE APPLICANT: EASTMAN HOLDING LTD. RECOMMENDATIONS: It is respectfully recommended that the General Purpose and Administration Committee recommend to Council the following: 1. THAT Report PSD-065-06 be received; 2. THAT the rezoning application submitted by Thyagarajah Sivakumer on behalf of Eastman Holding Ltd. be APPROVED and that the attached zoning by-law amendment be adopted by Council; and 3. THAT all interested parties listed in this report and any delegations be advised of Council’s decision. Submitted by: Reviewed by: David J. Crome, M.C.I.P., R.P.P. Franklin Wu, Director of Planning Services Chief Administrative Officer BH/CS/DJC/jd/df 30 May 2006 CORPORATION OF THE MUNICIPALITY OF CLARINGTON 40 TEMPERANCE STREET, BOWMANVILLE, ONTARIO L1C 3A6 T (905)623-3379 F (905)623-0830 REPORT NO.: PSD-065-06 PAGE 2 1.0 APPLICATION DETAILS 1.1 Owner: Eastman Holding Ltd. 1.2 Rezoning: from “General Commercial Zone (C1)” to include a gas station, car wash and convenience store in addition to permitted general commercial uses. The proposal is to construct an addition to the existing building and renovate the fuel pumps, tanks and canopy. The proposed drive-thru car wash is 111.32 square metres and includes a 10 car stacking lane. The second storey of the existing building would be converted to a caretaker residence. The service station would be removed and replaced with a convenience store. The existing building would also include the automotive parts retail store, and additional retail uses. 1.3 Location: 216 King Avenue East, Newcastle Village Part Lot 27, Concession 2, former Village of Newcastle 1.4 Date: Application received February 6, 2006. 2.0 BACKGROUND 2.1 Established prior to 1960, the site has been operating as a gas bar, automotive repair shop and automotive part retail store. 2.2 Site plan approval was issued in 1988 (DEV88-068) to expand the service bays, and further amended in 1994 (DEV 94-034) to permit the addition of a propane tank. 2.3 The site is serviced by municipal water and sewers. 3.0 PUBLIC NOTICE AND SUBMISSIONS 3.1 Public notice was given by mail to each landowner within 120 metres of the subject property and a public notice sign was installed on the King Avenue frontage. A public meeting was held by the Municipality on April 10, 2006, to consider concerns from local residents. 3.2 Concerns from the public meeting, telephone conversation and letters include: ? Lightning Levels ? Stacking requirements are too low. For similar car washes the queue can, at peak times, be up to 16 cars, which may result in cars stacking on King Avenue causing a hazardous traffic situation. ? The stacking lane is 10 m from residential property lines. The emissions from idling cars may have an effect on the air quality for the residents in the rear yard. ? Noise from the car wash and idling cars will in the queue have a negative impact on the surrounding residences. ? Signage and façade improvements REPORT NO.: PSD-065-06 PAGE 3 ? Hours of Operation 3.3 The applicant committed himself at the public meeting to work with staff to address these issues and improve the design. These comments will be addressed under section 9 of this report. 4.0 URBAN DESIGN AND SITE CHARACTERISTICS 4.1Located on the north side of King Avenue East, the lands are occupied by one building, and one gas bar with four pumping stations. The original building on the west side is one story with a white stucco façade, a blue parapet along the top and contains two bays for automotive repair; The east side is a two storey concrete block addition with one repair bay with the remainder of the space being used for automotive parts retail and storage. There are four fuelling pumps in front of the building and a propane dispenser is located on the west side of the site. The structure is setback approximately 19 metres from the street. The lands are relatively level with no significant environmental features close to the site. The site is mostly paved with a minimal amount of landscaping. 4.2 The car wash will be added on to the west side of the building, and a garbage enclosure and loading space provided at the east side. The scale of the additions is compatible with the existing building. However, the façade should be upgraded to improve the aesthetics of the community. REPORT NO.: PSD-065-06 PAGE 4 5.0 PROVINCIAL POLICY STATEMENT 5.1 The Provincial Policy Statement identifies settlement areas as the focus of growth and their vitality and regeneration should be promoted. Redevelopment of the site to include the convenience store, car wash and upgrades to the gas bar is consistent with the Provincial Policy Statement. 6.0 OFFICIAL PLAN CONFORMITY 6.1 The Durham Region Official Plan designates the subject property as Main Central Area. Convenience stores and automotive service station uses are permitted. This proposal is consistent with the Regional Official Plan. 6.2 Official Plan Amendment 43, adopted by Council on March 1, 2006, renamed the Newcastle Village “Main Central Area” to “Village Centre.” 6.3 Developments within Village Centres are planned with an integrated and diverse mix of uses. The pedestrian environment is paramount in all Village Centres and is enhanced through development which is human in scale, buildings of high architectural quality and pedestrian scale lighting. Public safety will be enhanced in the design and siting of buildings to provide visibility, easy access, multiple routes and unobstructive views from streets and buildings. These areas are to provide a diverse mix of uses and particularly redevelopment is encouraged to intensify with residential uses. 6.4 The Newcastle Village Centre Secondary Plan designates the property General Commercial Area. Objectives of this plan include emphasizing increased densities, quality urban design and to diversify retail uses. The Municipality, in cooperation with local businesses, will encourage façade and signage improvements. 7.0 ZONING BY-LAW CONFORMITY 7.1 The property is zoned “General Commercial Zone (C1)” which does not permit a convenience store, gas station, or car wash, hence the subject application. 7.2 The service station is a legal non-conforming use as it existed prior to the 1984 Zoning By-law. 8.0 AGENCY COMMENTS 8.1 In consideration of the nature of the application to allow a convenience store as an accessory use to an existing gas station, the application was circulated to a limited number of agencies. 8.2 There were no objections to rezoning the property to permit the gas bar, car wash and convenience store. Comments received primarily dealt with site plan servicing issues. REPORT NO.: PSD-065-06 PAGE 5 Engineering Services ? The entrances must be modified to a standard configuration and be aligned perpendicular to the roadway. ? A 2% cash-in-lieu of parkland contribution will be required from the applicant. ? All necessary securities for entrance works, storm sewer connection, and landscaping must be provided. Durham Regional Works ? Municipal servicing is available through an existing 200 mm watermain and an existing 300 mm sanitary sewer. ? As part of the site plan approval process, the applicant is required to submit: Water consumption rates; including anticipated peak demand ? Clarification on water recycling rates during car washes, if applicable ? Total discharge flows to the sanitary sewer; with clarification on how the solids ? disposal will be addressed ? The applicant is responsible for the full cost of any servicing required to accommodate the proposal. Veridian Connections ? A clear accommodation area for the corporation’s transformer must be provided. ? The applicant must make direct application to Veridian to obtain specific approval of the electrical service arrangements and related work for this project. 9.0 STAFF COMMENTS 9.1 King Avenue is the main east/west route through Clarington and Newcastle Village. Due to their high visibility, buildings along this road, and in particular within the Main Central Area, should demonstrate a high quality of urban design in their façades and landscaping. The proposal includes an upgrade to the existing façade to enhance architectural quality and complement the existing surrounding buildings. Upgrades include brick façade with mouldings, colour variations, and extra divisions and shutters around the second storey windows. 9.2 All signage will be shown on the site plan and is subject to site plan approval. The scale of the proposed signage will be appropriate for the development and will be consistent with other central area signs. 9.3 The applicant will submit a lighting plan prior to site plan approval, demonstrating zero light trespass at the property line. All light levels must comply with IESNA standards and the fixtures will be full cut-off. This will ensure adjacent property owners and traffic operation on King Avenue are not negatively impacted by this development. 9.4 A noise study has been prepared and submitted to determine the impact of the car wash on nearby residences. The study recommends that a 3 m sound barrier fence along the 60 m north property line and a 2.4 m sound barrier fence west of the car REPORT NO.: PSD-065-06 PAGE 6 vacuums be constructed. The study also recommends that the hours of operation for the car wash be limited to the day and evening periods only, preferably from 7:00 to 21:00. The applicant has agreed to limit the car wash hours of operation to the recommended time. 9.5 The existing hedge at the rear of the site is not an adequate noise barrier. The hedge will be removed and replaced with an acoustical wood fence. 9.6 The stacking requirement for a drive-through car wash is 10 cars to accommodate peak hour demands. This requirement is consistent with other car washes such as the one located at the corner of Highway 2 and Darlington Boulevard. 9.7 A new propane refill station will be installed on the property. Within the Propane Storage and Handling Code, the minimum distance between tank and property line for a propane refill centre is 3 metres provided that the tank capacity is less than 7500 Litres. 9.8 A landscaping plan has been provided. Landscaping will be further modified and upgraded through site plan approval. 9.9 If the rezoning is approved, Eastman Holdings Ltd. will be required to enter into a site plan agreement with the Municipality of Clarington prior to any building permit being issued. 9.10 Although responsibilities for remediation of contaminated sites have been delegated to the Municipality, the Fuels Safety Division of the Technical Standards and Safety Authority (TSSA) governs the remediation of existing gas station sites. Their protocol covers spills, leaks and the discovery of petroleum leaks and spills into the environment both on the property and beyond the property boundary and site restoration. The protocol includes surface and subsurface chemical remediation criteria for potable and non-potable groundwater environments. Normally, all necessary environmental reports and site remediation must be completed in advance of site plan approval. Although contamination may exist on operational gas station sites, the TSSA protocol was developed to permit gas stations to remain operational until site plan approval is granted and a building permit is issued. In conjunction with the building demolition and site redevelopment process, Eastman Holding Limited will conduct all necessary environmental studies to ensure that all contamination is removed to the satisfaction of TSSA. This permits the station to remain operational until the redevelopment phase is initiated. 10.0 RECOMMENDATIONS 10.1 Based on the comments in this report, it is respectfully recommended that the rezoning application be APPROVED as contained in Attachment 2. Attachments: Attachment 1 – Key Map Attachment 2 – By law REPORT NO.: PSD-065-06 PAGE 7 List of interested parties to be advised of Council's decision: Thyagarajah Sivakumar Joseph Miller REPORT NO.: PSD-065-06 INTERESTED PARTIES LIST Name Company Address City Province Postal Code Thyagarajah Sivakumar Eastman Holding 216 King Avenue East Newcastle, ON L2B 1H5 Ltd. Joseph Miller millerjoe@sympatico.ca (905)434-0687 THE CORPORATION OF THE MUNICIPALITY OF CLARINGTON BY-LAW NO. 2006-______ being a by-law to amend By-law 84-63, the Comprehensive Zoning By-law for the Corporation of the Municipality of Clarington WHEREAS the Council of the Corporation of the Municipality of Clarington deems it advisable to amend By-law 84-63, as amended, of the former Town of Newcastle in accordance with applications ZBA 2006-0003 and SPA2006-0004 to permit a convenience store and car wash as permitted uses; NOW THEREFORE BE IT RESOLVED THAT the Council of the Corporation of the Municipality of Clarington enacts as follows: 1. By adding a new Section 22.4.8 respecting lands zoned C7-8, as follows: “22.4.8 SERVICE STATION COMMERCIAL EXCEPTION (C7-8) ZONE Notwithstanding Section 21.3.i, and 22.1, those lands zoned C7-8 on the Schedules to this By-law shall be subject to the following zone regulations: a. Residential Uses i) Dwelling units as part of a building containing a permitted non-residential use(s). b. Non-Residential Uses i) Business, Professional or Administration Office; ii) Convenience Store; iii) Dry Cleaners Distribution Centre; iv) Laundry – coin-operated; v) Motor Vehicle Fuel Bar vi) Motor Vehicle Wash vii) Retail Commercial Establishment; viii) Service Shop, Light; viiii) Service Shop, Personal; c. Bulk Fuel Storage Tanks Bulk propane storage tanks located above ground shall be located in accordance with the provisions of the Propane Storage and Handling Code adopted by the Technical Standards and Safety Authority. 2. Schedule “5” to By-law 84-63 as amended, is hereby further amended by changing the zone designation from: “General Commercial (C1) Zone”, to “Service Station Commercial Exception (C7-8) Zone” as illustrated on the attached Schedule “A” hereto. 3. Attachment “A” attached hereto shall form part of this By-law. 4. This By-law shall come into effect on the date of the passing hereof, subject to the provisions of Section 34 of the Planning Act. BY-LAW read a first time this day of 2006 BY-LAW read a second time this day of 2006 BY-LAW read a third time and finally passed this day of 2006 ___________________ _ John Mutton, Mayor ___________________ Patti L. Barrie, Municipal Clerk